管开孔,用以床下一次风接口。水冷风室顶部水冷布风板采用钟罩
f式风帽,数量为:1size120000pt~size120000pt4炉size120000pt638个;5、6炉630个。布风板上留有3处排渣口,规格:size120000ptΦsize120000pt219X6、材质:1Cr18Ni9Ti中间开孔为事故排渣孔。水冷风室与水冷壁之间采用钢板连接,水冷风室与布风板的重量由水冷壁四墙共同分担。size120000pt炉膛出口出烟口仍然采用弯管结构,出烟口标高炉膛内两侧墙布置了6点负压测点。size120000pt炉膛给水引入管采用2根size120000ptΦsize120000pt377X10与2根size120000ptΦsize120000pt325X8集中下降管和12根size120000ptΦsize120000pt219X6的分散下降管,其中由2根size120000ptΦsize120000pt377X10的下降管分别引出4根分散下降管用于前后水冷壁给水,2根size120000ptΦsize120000pt325X8分别引出2根分散下降管共同连接于与两侧水下集箱相通置于炉膛前的size120000ptПsize120000pt形集箱,用于侧水冷壁给水。size120000pt炉膛热水引出管采用8根size120000ptΦsize120000pt219X6与6根size120000ptΦsize120000pt159X45管子,其中后墙混合集箱为8根size120000ptΦsize120000pt219X6管子,两侧墙各3根size120000ptΦsize120000pt159X45管子。size120000pt三、省煤器系统size120000pt本锅炉省煤器位于尾部对流烟道内,采用膜式结构,顺列布置,管子材质20G(GB3087),管子规格size120000ptΦsize120000pt42X4,横向节距108mm,纵向节距90160mm,沿高度方向分4组,省煤器入口给水集箱为环形集箱size120000ptΦsize120000pt426X20,给水经省煤器入口集箱进入84根size120000ptΦsize120000pt63X45省煤器吊挂管组,进入省煤器集箱size120000ptΦsize120000pt426X20,经此集箱进入蛇形管组加热向上进入size120000ptΦsize120000pt426X20的环形集箱,再由此环形集箱经12根size120000ptΦsize120000pt159X45连接管引至锅筒后部(其中两根经水冷屏后至锅筒后部)。管子材质:吊挂管材质为20G(GB531095),其余为20(GB308799)。size120000pt四、风系统及空预器size120000pt本锅炉风系统分一、二次及高压风系统,分别由单独的风机供给,一次、二次风均经过空气预热器后进入炉膛,其中一次风机供风占总风量的70,二次风机供风占总风量的28,高压风占总风量的2。size120000pt五、物料循环回路size120000pt本锅炉循环物料回路包括炉膛、分离器、回料阀,给煤经炉前3点进入炉膛密相区下部,燃烧并r